LigoWave Configuration

This article describes installation and configuration steps for WiFi LigoWave routers.


Configuring LigoWave router with your Start Hotspot account - step by step instructions

Connecting

Please reset LigoWave router to factory settings to avoid problems with some previous configuration.

Connect your Windows based computer by network cable to the LAN port.
Go to your computer Local Network Connection Properties.
Select Internet Protocol Version 4 (TCP/IP 4) then press on Properties.
Set IP address in 192.168.2.x range (be sure not to set 192.168.2.66, this IP address is reserved for communication with the router)
Ligowave setup1
Go to browser and in URL field type 192.168.2.66
Default login details are:
Username : admin
Password : admin01
Accept User Agreement if it appear and proceed with the setup with selecting Operating Country and press on Next.
Ligowave setup2
In next window select to use LigoWave as Standalone AP and press on Finish.
Ligowave setup3
Router will reset and when page is reloaded go to Settings panel Network Configuration section.
Select Network mode: Router IPV4 and configure WAN (eth0) IP method: Dynamic, DNS servers.
Obtain automatically in IP address field use address over which your LigoWave device connect to Internet.
From Status :: Device section you can check the installed software version.
Ligowave setup4

Configuring Parameters

From Status panel Statistics section see MAC address written on Interface counters for Wired eth0.
Here it is shown in format XX-XX-XX-XX-XX-XX.
We will need this information in XX-XX-XX-XX-XX-XXformat for future setup and for StartHotspot portal setup of your device MAC address.
LigoWave setup5
We will now go back to Settings panel Wireless Configuration section.
Under Network SSIDclick on configuration wheel button.
LigoWave setup6
Here you should set your SSID name and activate Broadcast SSID.
In Security Settings select Network SSID"HotSpot (UAM)".

In Radius section set as NAS ID your device MAC address in XX-XX-XX-XX-XX-XX format.
Other details should be same as at the screen bellow.
Primary server: 23.99.80.107
Authentication port: 1812 and Accounting port:1813
LigoWave setup7
At Captive portal section select External as Splash page type.
External Login URL: http://starthotspot.cloudapp.net/radlogin.
Logout URL: http://1.0.0.0 and press Done.
LigoWave setup8
Disconnect your computer wired cable from router.
From Configuration Changes window select to Save changes.

LigoWave setup9


If you need help with configuration, please go to starthotspot.com and contact our tech support. We'll be glad to help you.